Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros










Intervalo de ano de publicação
1.
ESC Heart Fail ; 8(5): 3845-3854, 2021 10.
Artigo em Inglês | MEDLINE | ID: mdl-34184426

RESUMO

AIMS: We tested the hypothesis that the effects of combined inspiratory muscle training and aerobic exercise training (IMT + AET) on muscle sympathetic nerve activity (MSNA) and forearm blood flow in patients with heart failure with reduced ejection fraction are more pronounced than the effects of AET alone. METHODS AND RESULTS: Patients aged 30-70 years, New York Heart Association Functional Class II-III, and left ventricular ejection fraction ≤40% were randomly assigned to four groups: IMT (n = 11), AET (n = 12), IMT + AET (n = 9), and non-training (NT; n = 10). MSNA was recorded using microneurography. Forearm blood flow was measured by venous occlusion plethysmography and inspiratory muscle strength by maximal inspiratory pressure. IMT consisted of 30 min sessions, five times a week, for 4 months. Moderate AET consisted of 60 min sessions, three times a week for 4 months. AET (-10 ± 2 bursts/min, P = 0.03) and IMT + AET (-13 ± 4 bursts/min, P = 0.007) reduced MSNA. These responses in MSNA were not different between AET and IMT + AET groups. IMT (0.22 ± 0.08 mL/min/100 mL, P = 0.03), AET (0.27 ± 0.09 mL/min/100 mL, P = 0.01), and IMT + AET (0.35 ± 0.12 mL/min/100 mL, P = 0.008) increased forearm blood flow. No differences were found between groups. AET (3 ± 1 mL/kg/min, P = 0.006) and IMT + AET (4 ± 1 mL/kg/min, P = 0.001) increased peak oxygen consumption. These responses were similar between these groups. IMT (20 ± 3 cmH2 O, P = 0.005) and IMT + AET (18 ± 3 cmH2 O, P = 0.01) increased maximal inspiratory pressure. No significant changes were observed in the NT group. CONCLUSIONS: IMT + AET causes no additive effects on neurovascular control in patients with heart failure with reduced ejection fraction compared with AET alone. These findings may be, in part, because few patients had inspiratory muscle weakness.


Assuntos
Insuficiência Cardíaca , Função Ventricular Esquerda , Exercício Físico , Insuficiência Cardíaca/terapia , Humanos , Músculos , Volume Sistólico
2.
Rev Bras Cir Cardiovasc ; 23(1): 60-9, 2008.
Artigo em Português | MEDLINE | ID: mdl-18719830

RESUMO

OBJECTIVES: Adjustable pulmonary trunk (PT) banding device may induce a more physiologic ventricle retraining for the two-stage Jatene operation. This experimental study evaluates the acute hypertrophy (96 hours) of the right ventricle (RV) submitted to an intermittent pressure overload. METHODS: Five groups of seven young goats were distributed according to RV intermittent systolic overload duration (0, 24, 48, 72 and 96 hours). The zero-hour group served as a control group. Echocardiographic and hemodynamic evaluations were performed daily. After completing the training program for each group, the animals were sacrificed for water content and cardiac masses evaluation. RESULTS: There was a significant increase in RV free wall thickness starting with the 48-hour group (p<0.05). However, a decreased RV ejection fraction, associated with an important RV dilation and a significant increase in the RV volume to mass ratio was observed at 24-hour training period, when compared to 96-hour period (p=0.003), with subsequent recovery throughout the protocol. A 104.7% increase in RV mass was observed in the 96-hour group, as compared to the control group, with no differences in water content between these two groups. The daily mean increase in RV mass during the study period was 21.6% +/- 26.8%. The rate of RV mass acquisition for the overall study period of intermittent systolic overload was 0.084 g/h +/- 0.035 g/h. CONCLUSION: Intermittent PT banding has allowed a significant RV mass acquisition in the 96-hour trained group. No myocardial water content changes were observed in this group, suggesting an increased myocardial protein synthesis.


Assuntos
Hipertrofia Ventricular Direita/fisiopatologia , Modelos Cardiovasculares , Transposição dos Grandes Vasos/cirurgia , Animais , Modelos Animais de Doenças , Cabras , Ventrículos do Coração/fisiopatologia , Hemodinâmica , Ligadura , Tamanho do Órgão , Sístole/fisiologia , Função Ventricular Direita/fisiologia
3.
Rev. bras. cir. cardiovasc ; 23(1): 60-69, jan.-mar. 2008. ilus
Artigo em Inglês, Português | LILACS | ID: lil-489701

RESUMO

OBJETIVO: A bandagem ajustável do tronco pulmonar (TP) pode proporcionar treinamento ventricular mais fisiológico para cirurgia de Jatene em dois estágios. Este estudo experimental analisa a hipertrofia aguda (96 horas) do ventrículo direito (VD) submetido à sobrecarga sistólica intermitente. MÉTODOS: Cinco grupos de sete cabritos jovens foram dispostos conforme o tempo de sobrecarga sistólica do VD (0, 24, 48, 72 e 96 horas). O grupo zero hora funcionou como grupo controle. Avaliações ecocardiográficas e hemodinâmicas foram feitas diariamente. Os animais foram sacrificados para avaliação do conteúdo de água e pesagem das massas cardíacas. RESULTADOS: Houve aumento da espessura do VD a partir de 48 horas de treinamento (p<0,05) e rebaixamento da fração de ejeção do VD, com dilatação importante desta câmara nas primeiras 24 horas do protocolo, recuperando-se posteriormente. Houve aumento da relação volume/massa nas primeiras 24 horas do protocolo, em relação ao momento 96 horas (p=0,003). A massa do VD apresentou aumento de 104,7 por cento no grupo 96 horas em relação ao controle. Não houve diferença quanto ao conteúdo de água do VD. A média diária de aumento da massa do VD foi de 21,6 por cento ± 26,8 por cento. A taxa de ganho de massa muscular do VD para todo o período de estudo foi de 0,084 g/h ± 0,035 g/h. CONCLUSÃO: O protocolo de bandagem intermitente do TP permitiu ganho de massa muscular do VD, significativa no grupo de 96 horas de estudo. Esta hipertrofia não foi acompanhada de aumento no conteúdo de água, o que sugere maior síntese protéica nos tecidos cardíacos.


OBJECTIVES: Adjustable pulmonary trunk (PT) banding device may induce a more physiologic ventricle retraining for the two-stage Jatene operation. This experimental study evaluates the acute hypertrophy (96 hours) of the right ventricle (RV) submitted to an intermittent pressure overload. METHODS: Five groups of seven young goats were distributed according to RV intermittent systolic overload duration (0, 24, 48, 72 and 96 hours). The zero-hour group served as a control group. Echocardiographic and hemodynamic evaluations were performed daily. After completing the training program for each group, the animals were sacrificed for water content and cardiac masses evaluation. RESULTS: There was a significant increase in RV free wall thickness starting with the 48-hour group (p<0.05). However, a decreased RV ejection fraction, associated with an important RV dilation and a significant increase in the RV volume to mass ratio was observed at 24-hour training period, when compared to 96-hour period (p=0.003), with subsequent recovery throughout the protocol. A 104.7 percent increase in RV mass was observed in the 96-hour group, as compared to the control group, with no differences in water content between these two groups. The daily mean increase in RV mass during the study period was 21.6 percent ± 26.8 percent. The rate of RV mass acquisition for the overall study period of intermittent systolic overload was 0.084 g/h ± 0.035 g/h. CONCLUSION: Intermittent PT banding has allowed a significant RV mass acquisition in the 96-hour trained group. No myocardial water content changes were observed in this group, suggesting an increased myocardial protein synthesis.


Assuntos
Animais , Hipertrofia Ventricular Direita/fisiopatologia , Modelos Cardiovasculares , Transposição dos Grandes Vasos/cirurgia , Modelos Animais de Doenças , Cabras , Hemodinâmica , Ventrículos do Coração/fisiopatologia , Ligadura , Tamanho do Órgão , Sístole/fisiologia , Função Ventricular Direita/fisiologia
4.
J Thorac Cardiovasc Surg ; 124(5): 999-1006, 2002 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-12407385

RESUMO

OBJECTIVE: An experimental model with a reversible pulmonary trunk banding device was developed with the aim of inducing rapid ventricular hypertrophy. The device consists of an insufflatable cuff connected to a self-sealing button. METHODS: The right ventricles of 7 young goats (average weight, 8.7 kg) were submitted to systolic overload and evaluated according to the hemodynamic, echocardiographic, and morphologic aspects. Baseline biopsy specimens were taken from the myocardium for microscopic analysis. The device was implanted on the pulmonary trunk and inflated so that a 0.7 right ventricular/left ventricular pressure ratio was achieved. Echocardiographic and hemodynamic evaluations were performed every 24 hours. Systolic overload was maintained for 96 hours. The animals were then killed for morphologic study. Another 9 goats (average weight, 7.7 kg) were used for control right ventricular weight. RESULTS: The systolic right ventricular/pulmonary trunk pressure gradient varied from 10.1 +/- 4.3 mm Hg (baseline) to 60.0 +/- 11.0 mm Hg (final). Consequently, the right ventricular/left ventricular pressure ratio increased from 0.29 +/- 0.06 to 1.04 +/- 0.14. The protocol group showed a 74% increase in right ventricular mass when compared with the control group. Serial 2-dimensional echocardiography showed a 66% increase in right ventricular wall thickness. There was a 24% increase in the mean myocyte perimeter, and the myocyte area increased 61%. CONCLUSIONS: The device is easily adjustable percutaneously, enabling right ventricular hypertrophy in 96 hours of gradual systolic overload. This study suggests that the adjustable pulmonary trunk banding might provide better results for the 2-stage Jatene operation and for the failed atrial switch operations to convert to the double-switch operation.


Assuntos
Ventrículos do Coração/patologia , Hipertrofia Ventricular Esquerda/etiologia , Hipertrofia Ventricular Direita/etiologia , Valva Pulmonar/patologia , Animais , Pressão Sanguínea/fisiologia , Modelos Animais de Doenças , Ecocardiografia Doppler , Desenho de Equipamento/efeitos adversos , Cabras , Ventrículos do Coração/citologia , Ventrículos do Coração/fisiopatologia , Hipertrofia Ventricular Esquerda/fisiopatologia , Hipertrofia Ventricular Direita/fisiopatologia , Microscopia , Modelos Cardiovasculares , Miócitos Cardíacos/metabolismo , Tamanho do Órgão/fisiologia , Valva Pulmonar/fisiopatologia , Volume Sistólico/fisiologia , Sístole/fisiologia , Função Ventricular Esquerda/fisiologia , Pressão Ventricular/fisiologia
5.
Rev. bras. cir. cardiovasc ; 15(4): 328-337, out.-dez. 2000. ilus, tab
Artigo em Português | LILACS | ID: lil-281971

RESUMO

OBJETIVO: Um dispositivo de bandagem do tronco pulmonar (TP) com ajuste percutâneo foi desenvolvido com o objetivo de induzir a hipertrofia rápida do ventrículo subpulmonar. MATERIAL E MÉTODOS: Consiste de um manguito de silicone insuflável percutaneamente, através de um botão de silicone auto-selante. Os corações de 7 cabritos jovens (peso médio: 8,7 kg) foram submetidos à sobrecarga sistólica imposta pelo dispositivo e avaliados sob os aspectos hemodinâmicos, ecocardiográficos e morfológicos. Foram extraídas biópsias basais do miocárdio do ventrículo direito (VD) para análise microscópica (perímetro e área do miócito). O dispositivo foi implantado no TP. As pressões do VD, TP e aorta foram monitorizadas. Após convalescença, foi iniciado o protocolo de insuflação do dispositivo de bandagem do TP. Foi injetada água destilada no botão auto-selante (via percutânea), até que a pressão sistólica do VD atingisse 70 por cento da pressão sistólica do VE. As avaliações ecocardiográfica e hemodinâmica foram realizadas a cada 24 horas. A sobrecarga sistólica do VD foi mantida por um período de 96 horas, com insuflações progressivas no limite máximo tolerado, a cada 24 horas. Após esse período, os animais foram sacrificados para análise morfológica dos corações. Outros 9 cabritos (peso médio: 7,7 kg) foram utilizados como grupo controle, para análise do peso do VD. RESULTADOS: Após 96 horas de sobrecarga sistólica do VD, foi observado um aumento do gradiente sistólico VD/TP de 10,1 + ou - 4,3 mmHg para 60,0 + ou - 11,0 mmHg e da pressão sistólica no VD de 22,4 + ou - 4,1 mmHg para 71,0 + ou - 10,0 mmHg (p<0,0001). O ecocardiograma revelou aumento da espessura muscular do VD, de 4,4 + ou - 0,5 mm para 7,3 + ou - 1,7 mm (p=0,001). Quando comparado ao grupo controle, houve um ganho de peso de 74 por cento do VD submetido à sobrecarga sistólica (p<0,0001). À microscopia óptica, foi observado aumento de 27 por cento no perímetro e de 69 por cento na área dos miócitos (p=0,0001). CONCLUSÕES: O dispositivo proposto neste trabalho é efetivo e facilmente ajustável por via percutânea, possibilitando a hipertrofia do ventrículo subpulmonar em 96 horas de sobrecarga sistólica. A melhora na ajustabilidade da bandagem do TP poderá permitir melhores resultados da operação de Jatene em dois estágios, nos pacientes com transposição das grandes artérias


Assuntos
Animais , Masculino , Bandagens , Hipertrofia Ventricular Direita/etiologia , Artéria Pulmonar/cirurgia , Ventrículos do Coração/cirurgia , Cateterismo , Insuflação/métodos , Transposição dos Grandes Vasos/cirurgia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...